Schneider Electric USA Website. Welcome to our website. How do I upgrade the firmware on an APC Network Management Card (NMC) or NMC embedded device (Rack PDU, etc)? Write a script which automatically performs the procedure. Alternatively, you can use APC's INI utility which is downloadable and explained in knowledge base FA156117. APC UPS Network Management Card 2 for Smart-UPS 1000 is rated 4.5 out of 5 by 13. I installed the utility program included with the network card to search and find the IP address on the network. Once found I logged in using the default user id and password listed in the manual. Rated 5 out of 5 by DaveN from Network Management Card It's.
. Remove all loads from the UPS. Turn off the UPS (Power button, front panel). Remove mains power from UPS.
Hold down power button (front panel) for 5 seconds to disconnect battery. Remove back panel where NMC is to be installed. Install NMC. Plug UPS back into mains. Connect Serial cable that came with NMC.
Attach to laptop. Download and run PuTTY – Telnet Client (or any alternative).
Connect with the following settings. Bits per second 9600. Data Bits 8.
Parity None. Stop bits 1. Flow Control None.
How to Avoid Equipment Damage. 1 Disconnect UPS power 1 Disconnect chassis power 1 How to Recover from a Lost Password. 2 Preliminary Information.
3 New standard features 3 Existing features 3 AP9618 features 3 AP9619 features 3 AP9618U and AP9619U upgrade kits 4 Integrated Environmental Monitor feature (AP9618 and AP9619) 4 Internal analog modem feature (AP9618) 4 Related documents 4 Inventory 5 Receiving and inspection 5 Please Recycle 5 Installation in a UPS. 6 Overview 6 Step 1: Turn off all power (Smart-UPSor Matrix-UPS)6 Step 2: Install the Network Management Card 7 Expansion/Triple Chassis Installation. 8 Overview 8 When to use the AC adapter (AP9505) 8 Step 1: Disconnect the chassis from all power 8 Step 2: Install the Network Management Card 9.
Contents Quick Configuration. 10 Overview 10 TCP/IP configuration methods 10 APC Management Card Wizard 11 BOOTP & DHCP configuration 11 Local access to the control console 14 Remote access to the control console 15 Control console 16 How to Access a Configured Network Management Card. 17 Overview 17 Web interface 17 Telnet 17 SNMP 17 FTP 18 APC Management Card Wizard 18 Analog modem (AP9618) 18. How to Avoid Equipment Damage Disconnect UPS You do not need to turn off a Symmetra ® or a Silcon ™ model power UPS to install the Management Card. Damage to the UPS or APC Network Management Card (AP9617 or AP9618) can result if you do not remove all AC and DC power from a Smart-UPS ® or Matrix-UPS ®,Expansion Chassis, or a Triple Caution Expansion Chassis before you install the Management Card.
Turn off the equipment that connects to the UPS. Disconnect the UPS from its AC input source. Press the OFF button on the UPS for approximately five seconds to turn off the DC (battery) power. Matrix-UPS 1. Turn off the equipment that connects to the UPS. Turn off the circuit breaker on the rear panel of the UPS. Disconnect Make sure that any Expansion Chassis or Triple Expansion chassis power Chassis is disconnected from all power: disconnect the chassis cable from the UPS and, if the AC-to- DC Adapter (AP9505) option is used, disconnect the adapter from the chassis.
How to Recover from a Lost Password You can use a local computer, a computer that connects to the Management Card through the serial port at the Management Card’s UPS, Expansion Chassis, or Triple Expansion Chassis, to access the control console. Select a serial port at the local computer and disable any service that uses that port. Unless an APC smart-signalingcable (940-0024or 9401524) is already connected to the selected port, connect the smart-signalingcable that came with the Management Card to the selected port and to the serial port at the Management Card’s UPS or chassis.
Run a terminal program (such as HyperTerminal) and configure the selected port for 2400 bps, 8 data bits, no parity, 1 stop bit, and no flow control, and save the changes. Press E NTER to display the User Name prompt. Press the reset button on the Management Card. Press E NTER and use apc for the User Name and Password. (If you take longer than 30 seconds to log on, you will need to repeat steps 4 and 5.) 7. Select System in the Control Console menu and User Manager in the System menu. Select Administrator and follow the on-screeninstructions to change the User Name and Password settings, both of which are now defined as apc.
Press C TRL -C and log off. Reconnect any cable disconnected in step 2, and restart any service disabled in step 1.
Preliminary Information AP9618U and You can use an AP9618U kit to convert an AP9617 Network AP9619U Management Card EX or an AP9619 Network Management upgrade kits Card EM into an AP9618 Network Management Card EM/ MDM. You can use an AP9619U kit to convert an AP9617 Network Management Card EX into an AP9619 Network Management Card EM. Integrated The AP9618 and AP9619 Management Cards include an Environmental Integrated Environmental Monitor that provides the following Monitor feature features: (AP9618 and. A temperature/humidly probe AP9619). Two input contacts.
Two-positionoutput relay In addition to the Integrated Environmental Monitor, an AP9618 or AP9619 Management Card can still monitor and manage an external Environmental Monitoring Unit or Environmental Monitoring Card. Internal analog An AP9618 Network Management Card EM/MDM has an modem feature internal analog modem that provides for the following out-of- (AP9618) band communication:. Dial-outnotifications for APC’s Remote Monitoring Service (RMS). Dial-inaccess to the Management Card’s Console Interface Related The APC Network Management Card utility CD contains the documents following documentation:. Network Management Card User’s Guide (. Doc usrguide.pdf ). Management Card Addendum (.
Doc addendum.pdf ). PowerNet ® Management Information Base (MIB) Reference Guide (. Doc mibguide.pdf ).
CD-ROM contents file (. Content.txt ). Network Management Card Release Notes (. Relnotes.txt ). Installation instructions in text format (.
Install.txt). Troubleshooting documents (. Trouble.).
Preliminary Information Inventory The Management Card package includes the following items:. This Installation and Quick Start Guide. Network Management Card. APC Network Management Card utility CD. Smart-signalingcable.
Installation of Multiple Management Cards sheet. Declaration of Conformity. Warranty registration form.
Network Management Card quality assurance test slip Save the assurance test slip. The slip contains the MAC address that you may need when performing the procedures outlined in “Quick Note Configuration” on page 10.
Inspect the package and contents for shipping damage, and make sure that all parts were sent. Report any damage immediately to the shipping agent, and report missing contents, damage, or other problems immediately to APC or your APC reseller. The Network Management Card is sensitive to static electricity. When handling the Management Card, touch only the end plate while using one or more of these electrostatic- Caution discharge devices (ESDs): wrist straps, heel straps, toe straps, or conductive shoes. The shipping materials are recyclable.
Please save them for later use, or dispose of them appropriately. APC management products, including the Network Management Card, contain removable, lithium coin-cellbatteries.
When discarding these batteries, you must follow local rules for recycling. You can install the Management Card in a card slot in a Smart-UPS, Matrix-UPS,or Symmetra. For a Silcon UPS, the Management Card installs in a Silcon Triple Expansion Chassis (AP9604S). You do not need to turn power off for a Symmetra UPS.
Damage to the UPS or Management Card can result if you do not remove all AC and DC power from a Smart-UPSor Matrix-UPSmodel UPS. Caution Smart-UPS 1. Turn off the equipment that connects to the UPS. Disconnect the UPS from its AC input source. Press the OFF button on the UPS for approximately five seconds to turn off the DC (battery) power.
Matrix-UPS 1. Turn off the equipment that connects to the UPS.
![Network Network](http://www.apc.com/resource/images/salestools/500/Miscellaneous/2BCF960F80313DF285257B0B005A130D_EWAR_94PMDA_misc_h_500x500.jpg)
Turn off the circuit breaker on the rear panel of the UPS.